Maximum internal pressure to be sealed

Symbol pimax
Unit N/mm²
Attribute-ID vdi_2230_maximum_internal_pressure_to_be_sealed
Numeric ID 12126
Value Type PMTechValue

The maximum internal pressure to be sealed pimax is used together with the sealing area AD to calculate the minimum clamp load required for a sealing function FKP (R2). The sealing area is calculated internally from the interface area minus the bore.