| Symbol | - |
|---|---|
| Unit | - |
| Attribute-ID | vdi_2230_bending_moment_from_deformation_of_flange |
| Numeric ID | 19358 |
| Value Type | PMString |
For thin-walled flanges that are loaded by internal pressure, the bolts are subjected to additional bending moment due to flange deformation. Optionally, this influence can be taken into account here by increasing the axial force acting on the bolts by a factor of 1.25.