Scaling factor for envelope cuts

Symbol fcuts
Unit -
Attribute-ID scaling_factor_for_envelope_cuts
Numeric ID 201894
Value Type PMDouble

The grid fineness for determining the actual contour from the envelope sections is auomatically adjusted to the tooth size (module). If problems still arise when determining the actual contour, the grid fineness can be further adjusted using the scaling factor fcuts.

Note: If points cannot be found at the start or end of the contour, the grid size should be reduced (fcuts < 1.0). If no valid contour can be found, the grid size should be increased (fcuts > 1.0).