Alternating load during nominal operation

Symbol -
Unit -
Attribute-ID reverse loading
Numeric ID 2816
Value Type PMBoolean

Activation of this switch assumes reversing operation for the load capacity calculation of the worm gear stage, in which the leading and trailing flanks are loaded in equal proportions. In this case, additional safety values which have been corrected by the alternating load factor YW = 0.7 according 1) are output in addition to the tooth root safeties calculated according to the standard. 

Reversing operation has little or no significant effect on the damage criteria of wear, deflection, and temperature. With regard to the pitting criterion, it can be assumed that the flank is relieved during reversing operation, as both the leading and trailing flanks of the worm wheel are loaded. For this reason, the load cycles specified by the user for the pitting load capacity calculation are halved for reversing operation or alternating load. 

1) Brinck, P.: Tooth root load capacity of surface-hardened cylindrical gears with load direction reversal. Dissertation, Technical University of Munich (1989)