Total number of mesh positions

Symbol -
Unit -
Attribute-ID total_number_of_mesh_positions_system_rolling_analysis
Numeric ID 201193
Value Type PMInteger

The number of mesh positions per pitch for the fastest stage when calculating the excitation in the system.

Only fixed values in steps of 6 between 12 and 72 can be selected, as the number of Fourier coefficients is calculated from the number of mesh positions divided by 6.

This is due to the fact that at least 6 interpolation points are required to clearly describe a sinus curve by a Fourier transformation.