Total ventilation loss torque according to Maurer

Symbol TV
Unit Nm
Attribute-ID total_ventilation_loss_torque_maurer
Numeric ID 18275
Value Type PMTechValue

Total ventilation loss torque, TV,  for injection lubrication according to Maurer:

PVZ0_V=PVZ0_V,1+PVZ0_V,2+PVZ0_V,mesh

TV,i=PVZ0_V,i+PVZ0_V,mesh2·π·ni, gear i is drivenPVZ0_V,i2·π·ni, gear i drives

PVZ0_V
Total ventilation losses
PVZ0_V,mesh Ventilation loss in mesh
PVZ0_V,1
Ventilation loss, gear 1
PVZ0_V,2
Ventilation loss, gear 2
TV,i Total ventilation loss torque, gear i
ni Rotational speed, gear i