Clamping length of the second plate

Symbol lK2
Unit mm
Attribute-ID vdi_2230_clamping_length_of_the_second_disc
Numeric ID 12161
Value Type PMTechValue

The 2nd plate section is described by the following attributes:

The clamping length of the second plate lK2 corresponds to the thickness of the component in the clamped region.

The Young's modulus of the second clamped part EP2 is required for the calculation of the plate resilience.