| Symbol | - |
|---|---|
| Unit | - |
| Attribute-ID | reverse loading |
| Numeric ID | 2816 |
| Value Type | PMBoolean |
With this switch, a reversing operation is assumed for the load capacity calculation of the worm gear stage, in which the leading and trailing flanks are loaded in equal proportions. In this case, additional safety values corrected by the alternating load factor YW = 0.7 after 1) are output in addition to the tooth root units calculated according to the standard.
Reversing operation has no or only insignificant effects on the damage criteria of wear, deflection and temperature. With regard to the pitting criterion, it can be assumed that the flank is relieved during reversing operation, as both the leading and trailing flanks of the worm gear are loaded. For this reason, the load cycles specified by the user for the dimple load capacity calculation are halved for reversing operation or alternating load.
1) Brinck, P.: Tooth root load capacity of surface-hardened cylindrical gears with load direction reversal. Dissertation, Technical University of Munich (1989)