Ratio factor for minimum load

Symbol fmin
Unit -
Attribute-ID vdi_2230_ratio_of_axial_force
Numeric ID 19505
Value Type PMDouble

This factor can be used to determine the minimum loads for a dynamic load in the multiple bolt calculation from the specified axial force or from the specified pressure.